home > Air pressure sensor principle > Anti-jamming measures for Air Pressure Sensors

Anti-jamming measures for Air Pressure Sensors

time£º2018-04-20 13:42    source£ºair pressure sensor

 Anti-jamming measures for Air Pressure Sensors

 
(1) Maintain stability
 
Most sensors will experience "drift" after overtime work, so it is necessary to understand the stability of the sensor before purchase. This kind of pre-work can reduce all kinds of troubles in future use.
 
 (2) Pressure sensor package
 
Sensor packaging, in particular, is often easy to ignore is its rack, but this will gradually expose its shortcomings in the future. It is important to consider the sensor working environment, humidity, and how to install the sensor in the optional transmitter. Will there be strong impact or vibration?
 
(3) Select output signal
 
What kind of output signal the pressure sensor needs to get: mV, V, mA and frequency output digital output, depending on many factors, including the distance between the sensor and the system controller or display, whether there is "noise" or other electronic interference signals. Do you need amplifiers, amplifier locations, etc. For many OEMs with short distances between sensors and controllers, the most economical and effective solution is to use a mA-output sensor. If you need to amplify the output signal, it is best to use a sensor with built-in amplification. For long-distance transmission or presence of strong electronic interference signals, it is best to use a mA-level output or a frequency output. In environments with high RFI or EMI specifications, special protection or filters must be considered in addition to the need to select mA or frequency output. (At present, due to the needs of various acquisitions, there are many kinds of output signals of pressure sensors on the market, mainly 4-20mA, 0-20mA, 0-10V, 0-5V, etc., but 4-20mA is more commonly used. 0-10V two kinds, in these output signals that I lift above, only 2-20mA is two-wire system, what we call the output is a few-wire system does not include grounding or shielded wire, the others are three-wire system).
 
(4) Select the excitation voltage
 
The type of output signal determines what kind of excitation voltage is selected. Many amplification sensors have built-in voltage regulators, so their supply voltage range is large. Some delivery devices are quantitatively configured and require a stable working voltage. Therefore, a working voltage that can be obtained determines whether a sensor with a regulator is used. When selecting the transmitter, the working voltage and the system cost must be comprehensively considered.
 
(5) Do you need an interchangeable sensor?
 
Determine if the required sensor can accommodate multiple use systems. In general, this is important. Especially for OEM products. Once the product is delivered to the customer, the cost of the customer's calibration is considerable. If the product has good interchangeability, then even changing the sensor used will not affect the overall system performance.
 
(6) Others
 
After confirming some of the above parameters, we also need to confirm the process connection interface of your pressure sensor and the supply voltage of the pressure sensor; if you use it under special circumstances, you should also consider explosion protection and protection class.

air pressure sensor Related articles

The origin of 4-20mA gas pres
2018-04-26
Pressure sensor operating temp
2018-04-26
The importance of air pressure
2018-04-26
SHELOK pressure sensor classi
2018-04-26
Pressure sensor wiring method
2018-04-26
Pressure sensor development
2018-04-26
Intelligent pressure transmitt
2018-04-26
Application of New Pressure Se
2018-04-26